README.txt for BCM2.5 RC6.3-GA Patch 3.0 - Patch ID:30366297 

1. Problem description
SR # 30366297 No ISDN ISP access because User Name Field to short in Unified Manager
SR Text:
This was found by a Beta Trial Site in Germany by Willy Kobler and I reproduced it here in UK:
Scenario:
RC6.3 7.1.7 German Profile.
To access ISP (T-Onlin- Deutsche Telekom) via ISDN Dial-out, the user name contains more than 20 charcters. Example User Name:

000673357681,670059352676#001@t-online.de

It was working in B1.7 6.2.8

This is the same in UK profile.

Further Information:
I have re-created this issue on my BCM 2.5 Rel 7.1.7 and Willy is correct no more than 20 characters allowed in Unified Manager User Name field. 
I then created the same Dial Up connection using WINNT and VNC and it works perfectly. 
This is a limitation of the Unified Manager not WINNT.

2. Solution description
Java GUI gets the display length from susbsys.cfg which limits the name length to 20 characters.
All we need to do is to increase the name field length to 50.

3. List of SR's resolved
- SR 30366297

4. Software components changed
- subsys.cfg

5. Applicable EE releases and affected profiles
- EE release: BCM2.5 RC6.3-GA
- Affected Profiles:

6. Installation guide
- Go to command prompt
- Type "Miserver /shutdown"
- Copy subsys.cfg to "c:\program files\nortel networks\unified manager\config" directory and overwrite the old one
- Resetsubsys

7. System downtime required
- 

8. Emergency recovery procedure or back out plan if patch fails
- 

9. List of prerequisite patch(s) - This addresses the so called "patch on patch" situation
- None.

10. List of previous patch(s) included in the current one
- None.  

11. Misc Notes
- None